High Accuracy One Step Syphilis Rapid Diagnostic test Whole Blood/SerumPlasma specimen Gold Colloidal Method

  • 1
  • 2
  • 3

Brand Name : New Life

Certification : ISO13485,

Place of Origin : China

MOQ : 5000pcs

Price : USD0.1-USD1

Payment Terms : T/T, Western Union

Supply Ability : 10000000pcs/month

Delivery Time : 20-30days

Packaging Details : 1pc/pouch, 25pcs/box

Category : Infectious

Format : Strip/cassette

Specimen : Whole Blood/Serum/Plasma

Testing time : 5-15 minutes

Shelf Life : 24 Months

Application : Syphilis test

Accuracy : 99.915%

Contact Now

High Accuracy One Step Syphilis Rapid Diagnostic test Whole Blood/SerumPlasma specimen Gold Colloidal Method

Product Name:


Syphilis Rapid Diagnostic test

Intended Use:

The Syphilis Rapid Test Device (Whole Blood/Serum/Plasma) is a rapid chromatographic immunoassay for the qualitative detection of antibodies (IgG and IgM) to Treponema Pallidum (TP) in whole blood, serum or plasma to aid in the diagnosis of Syphilis.

Summary:

Treponema Pallidum (TP) is the causative agent of the venereal disease Syphilis. TP is a spirochete bacterium with an outer envelope and a cytoplasmic membrane.1 Relatively little is known about the organism in comparison with other bacterial pathogens. According to the Center for Disease Control (CDC), the number of cases of Syphilis infection has markedly increased since 1985.2 Some key factors that have contributed to this rise include the crack cocaine epidemic and the high incidence of prostitution among drug users.3 One study reported a substantial epidemiological correlation between the acquisition and transmission of the HIV virus and Syphilis.4

Multiple clinical stages and long periods of latent, asymptomatic infection are characteristic of Syphilis. Primary Syphilis is defined by the presence of a chancre at the site of inoculation. The antibodies response to the TP bacterium can be detected within 4 to 7 days after the chancre appears. The infection remains detectable until the patient receives adequate treatment.5

The Syphilis Rapid Test Device (Whole Blood/Serum/Plasma) utilizes a double antigen combination of a Syphilis antigen coated particle and Syphilis antigen immobilized on membrane to detect TP antibodies (IgG and IgM) qualitatively and selectively in whole blood, serum or plasma.

TEST PROCEDURE

1. Bring the pouched test device to room temperature(15-30℃) prior to testing. Do not open pouch until ready to perform the assay.

2. Remove the test device from the sealed pouch. Lay it on a flat, clean and dry surface.

3. Use the pipette to draw and slowly add 1 drop of whole blood/serum/plasma to the sample well.

4. Hold the buffer vertically and add 1 drop to the sample well. /If using a pipette, change a new one to avoid cross-contamination. Draw and transfer 2 drops of buffer to the sample well.

5. Interpret test results within 10-15 minutes. Do not interpret after 20 minutes.

Caution: The above interpreting time is based on room temperature range of 15-30℃. If your room temperature is significantly lower than 15℃, then the interpreting time should be properly increased to 30 minutes.

INTERPRETATION OF RESULTS

Positive:

Two red lines are visible in the result window. The intensity of the test line may be weaker or darker than that of the control line. This still means a positive result.

Negative:

The control line appears in the result window, but the test line is not visible.

Invalid:

If the control line does not appear in the result window, the test results are INVALID regardless of the presence or absence of the line in the test region.

PERFORMANCE CHARACTERS:

Clinical Sensitivity, Specificity and Accuracy

The Syphilis Rapid Test Device (Whole Blood/Serum/Plasma) has correctly identified specimens of a seroconversion panel and has been compared to a leading commercial TPHA Syphilis test using clinical specimens. The results show that the relative sensitivity of The Syphilis Rapid Test Device (Whole Blood/Serum/Plasma) is 99.5% and the relative specificity is 99.3%.

Syphilis Rapid Test Device vs. TPHA

Method TPHA Total Results
Syphilis Rapid Test Device Results Positive Negative
Positive 394 4 398
Negative 2 540 542
Total Results 396 544 940

Relative sensitivity: 99.5% (98.2%-99.9%)* Relative specificity: 99.3% (98.1%-99.8%)*

Accuracy: 99.4% (98.6%-99.8%)* * 95% Confidence Intervals

NOTE: Insufficient specimen volume or incorrect procedural techniques are the most likely reasons for the control line failure. Review the procedure and repeat the test with a new device. If problem persists, please contact your local distributor.

High Accuracy One Step Syphilis Rapid Diagnostic test Whole Blood/SerumPlasma specimen Gold Colloidal Method

ORIENT NEW LIFE MEDICAL CO., LTD.
Contact: Jerry Meng
Email: Jerry @ newlifebiotest .com
Tel. +86 18657312116
SKYPE enetjerry

Product Tags:

bacterial infection blood test

      

home blood test kit

      
Buy cheap High Accuracy One Step Syphilis Rapid Diagnostic test Whole Blood/SerumPlasma specimen Gold Colloidal Method product

High Accuracy One Step Syphilis Rapid Diagnostic test Whole Blood/SerumPlasma specimen Gold Colloidal Method Images

Inquiry Cart 0
Send your message to this supplier
 
*From:
*To: Orient New Life Medical Co.,Ltd.
*Subject:
*Message:
Characters Remaining: (0/3000)